Vacuum Decay
The vacuum attenuation technology has been developed for decades. It is a physical container integrity test method. With the development of the times and technological progress, the test method is constantly improving.
key word:
Category:
Technologies
Hotline:
The vacuum attenuation technology has been developed for decades. It is a physical container integrity test method. With the development of the times and technological progress, the test method is constantly improving.
Vacuum attenuation has been proved to be one of the practical, sensitive and stable nondestructive vessel integrity testing methods. This test provides reliable, repeatable and accurate quantitative results and is a very practical deterministic testing method.
The MD series vacuum attenuation test instrument provided by BMI can detect the container leakage of at least 1 micron.
Vacuum attenuation technology:
The MD leakage tester is connected to the test chamber specially designed to contain the package to be tested. The package is placed in the test chamber, and then the test chamber is vacuumized with a certain index; The sensor monitors the vacuum level in the chamber and the vacuum change within the predetermined test time. The vacuum change indicates whether there is leakage and defect in the package; The sensitivity of the test is related to the test instrument, test chamber, parameter settings, etc.
The test system can be designed to be manual or fully automatic. This inspection method is applicable to offline testing in the laboratory or sampling inspection around the production line for QA/QC statistical process control. According to different samples, the test beat is several seconds to tens of seconds.
BMI has many special technical advantages in vacuum attenuation technology. Its advanced testing instruments, together with the patented test chamber and the patented test device with locking function, solve the external interference factors in physical testing and measurement, control the volume of the testing system and greatly improve the signal-to-noise ratio between OK products and NG products.
The MD leakage tester meets ASTM test methods and FDA standards, complies with CDE (Technical Guide for Sealing Research of Chemical Injection Packaging System), and complies with the regulatory requirements of 21CFR Part 11 on data integrity.

Core Instruments MD-750
Summary
◈ MD-750 series leak detector, mainly used for container airtight integrity test (CCIT)
◈ Meet ASTM test methods and FDA standards
◈ In line with CDE (Technical Guide for Sealing Research of Chemical Injection Packaging System)
◈ Comply with the regulatory requirements of 21CFR Part 11 on data integrity
Advantage
◈ Safe, nondestructive, fast, sensitive and accurate
◈ high sensitivity
◈ high resolution
◈ Aleak TS professional test software
◈ Real time test process curve
◈ Counting statistics and SPC functions
◈ Exportable PDF report
◈ Audit tracking and calibration capability
◈ Anodized aluminum case, light and corrosion resistant
Previous page
Next page
Previous page
Next page
Related information